Table – Lenovo 3797 User Manual
Page 165

Table
16.
Power-supply
LEDs
Power-supply
LEDs
Description
Action
Notes
AC
DC
Error
Off
Off
Off
No
ac
power
to
the
server
or
a
problem
with
the
ac
power
source
1.
Check
the
ac
power
to
the
server.
2.
Make
sure
that
the
power
cord
is
connected
to
a
functioning
power
source.
3.
Turn
the
server
off
and
then
turn
the
server
back
on.
4.
If
the
problem
remains,
replace
the
power
supply.
This
is
a
normal
condition
when
no
ac
power
is
present.
Off
Off
On
No
ac
power
to
the
server
or
a
problem
with
the
ac
power
source
and
the
power
supply
had
detected
an
internal
problem
1.
Replace
the
power
supply.
2.
Make
sure
that
the
power
cord
is
connected
to
a
functioning
power
source.
This
happens
only
when
a
second
power
supply
is
providing
power
to
the
server.
Off
On
Off
Faulty
power
supply
Replace
the
power
supply.
Off
On
On
Faulty
power
supply
Replace
the
power
supply.
On
Off
Off
Power
supply
not
fully
seated,
faulty
system
board,
or
faulty
power
supply
1.
Reseat
the
power
supply.
2.
If
the
240V
failure
LED
on
the
system
board
is
lit,
have
the
system
board
replaced
(trained
service
technician
only).
3.
If
the
240V
failure
LED
on
the
system
board
is
not
lit,
replace
the
power
supply.
Typically
indicates
that
a
power
supply
is
not
fully
seated.
On
Off
or
Flashing
On
Faulty
power
supply
Replace
the
power
supply.
On
On
Off
Normal
operation
On
On
On
Power
supply
is
faulty
but
still
operational
Replace
the
power
supply.
Chapter
7.
Solving
problems
149