Table

16.

Power-supply

LEDs

Power-supply

LEDs

Description

Action

Notes

AC

DC

Error

Off

Off

Off

No

ac

power

to

the

server

or

a

problem

with

the

ac

power

source

1.

Check

the

ac

power

to

the

server.

2.

Make

sure

that

the

power

cord

is

connected

to

a

functioning

power

source.

3.

Turn

the

server

off

and

then

turn

the

server

back

on.

4.

If

the

problem

remains,

replace

the

power

supply.

This

is

a

normal

condition

when

no

ac

power

is

present.

Off

Off

On

No

ac

power

to

the

server

or

a

problem

with

the

ac

power

source

and

the

power

supply

had

detected

an

internal

problem

1.

Replace

the

power

supply.

2.

Make

sure

that

the

power

cord

is

connected

to

a

functioning

power

source.

This

happens

only

when

a

second

power

supply

is

providing

power

to

the

server.

Off

On

Off

Faulty

power

supply

Replace

the

power

supply.

Off

On

On

Faulty

power

supply

Replace

the

power

supply.

On

Off

Off

Power

supply

not

fully

seated,

faulty

system

board,

or

faulty

power

supply

1.

Reseat

the

power

supply.

2.

If

the

240V

failure

LED

on

the

system

board

is

lit,

have

the

system

board

replaced

(trained

service

technician

only).

3.

If

the

240V

failure

LED

on

the

system

board

is

not

lit,

replace

the

power

supply.

Typically

indicates

that

a

power

supply

is

not

fully

seated.

On

Off

or

Flashing

On

Faulty

power

supply

Replace

the

power

supply.

On

On

Off

Normal

operation

On

On

On

Power

supply

is

faulty

but

still

operational

Replace

the

power

supply.

Chapter

7.

Solving

problems

149