Siemens Industrial Ethernet Switches SCALANCE X-200 User Manual
Page 51
Product properties
3.9 SCALANCE X204-2 / SCALANCE X204-2TS
SCALANCE X-200
Operating Instructions, 12/2011, A5E00349864-19
51
3.9.2
SCALANCE X204-2 / SCALANCE X204-2TS TP interfaces
Connector pinout
On the SCALANCE X204-2 and SCALANCE X204-2TS devices, the TP interfaces take the
form of RJ-45 jacks with the MDI-X assignment (Medium Dependent Interface
Autocrossover) of a network component.
Figure 3-12 RJ-45 jack
Table 3- 9
Pin assignment
Pin number
Assignment
Pin 8
n. c.
Pin 7
n. c.
Pin 6
TD-
Pin 5
n. c.
Pin 4
n. c.
Pin 3
TD+
Pin 2
RD-
Pin 1
RD+
NOTICE
TP cords or TP-XP cords with a maximum length of 10 m can be connected to the RJ-45
TP port.
With the IE FC cables and IE FC RJ-45 plug 180, an overall cable length of a maximum of
100 m is permitted between two devices depending on the cable type.