5

Connection

5.1

Power supply

Power supply

The power supply is connected using a 4-pin plug-in terminal block.
The power supply is connected over a high resistance with the enclosure to allow an

ungrounded set up. The power supply is non-floating. The signal cables of the Ethernet TP

ports are floating.

SCALANCE X204 IRT PRO, X202-2P IRT PRO and X201-3P IRT PRO

The power supply connector of the SCALANCE X204 IRT PRO, SCALANCE X202-2P IRT

PRO and SCALANCE X201-3P IRT PRO is connected using a Power Plug PRO

(PROFINET-compliant connector technology)

These two devices also have two 24 V power connectors, one for the switched mode and

one for the unswitched 24 V power supply (two plug-in power connectors). Using these

power interfaces (L1+, N1 and L2+, N2), it is possible to loop through the power for ET200

PRO with PROFINET-compliant connector technology. It is also possible to supply power to

the module via an external T-piece (device supply over only one power interface).
SCALANCE X204 IRT PRO, X202-2P IRT PRO and X201-3P IRT PRO

Metal or plastic connectors (6GK1907-0AB10-6AA0) can be used for the power supply of the

devices.

Note

If the devices are used in an ambient temperature in excess of 40 °C, or if currents higher

than 6 A are conducted via the connector, metal connectors must be used.

Note
In areas subject to the National Electric Code (NEC), the Canadian Electric Code (CEC) and

the EU directive 94/9 (ATEX), metal connectors must be used.

SCALANCE X-200
Operating Instructions, 12/2011, A5E00349864-19