beautypg.com

26 c-plug (configuration plug) – Siemens Industrial Ethernet Switches SCALANCE X-200 User Manual

Page 116

background image

Product properties

3.26 C-PLUG (configuration plug)

SCALANCE X-200

116

Operating Instructions, 12/2011, A5E00349864-19

3.26

C-PLUG (configuration plug)

Area of application

The C-PLUG is an exchangeable medium for storage of the configuration and project

engineering data of the basic device. This means that the configuration data remains

available if the basic device is replaced.

How it works

Power is supplied by the basic device. The C-PLUG retains all data permanently when the

power is turned off.
If an empty C-PLUG (factory settings) is inserted, all configuration data of an IE

Switch X-200 is saved to it when the device starts up. Changes to the configuration during

operation are also saved on the C-PLUG without any operator intervention being necessary.
If a C-PLUG is inserted, the configuration stored internally on the basic device is no longer

changed. Al changes made to the configuration during ongoing operation are only stored on

the C-PLUG.
A basic device with an inserted C-PLUG automatically uses the configuration data of the

C-PLUG when it starts up. This is, however, only possible when the data was written by a

compatible device type.
This allows fast and simple replacement of the basic device. If a device is replaced, the C-

PLUG is taken from the failed component and inserted in the replacement device. The first

time it is started up, the replacement device has the same configuration as the failed device

except for the MAC address set by the vendor.

Compatible devices

As a general rule, the data on the C-PLUG is only compatible with devices having an

identical order number and the same device name.
The device combinations shown in the following table are exceptions. With these devices,

the exchange of the C-PLUG is possible in one direction.

Table 3- 25 Device combinations between which the C-PLUG can be exchanged:

Device type
SCALANCE

C-PLUG created by device with
order number

Compatible with device with
order number

X208

6GK5208-0BA00-2AA3

6GK5208-0BA10-2AA3

X204-2

6GK5204-2BB00-2AA3

6GK5204-2BB10-2AA3

X206-1

6GK5206-1BB00-2AA3

6GK5206-1BB10-2AA3

X204-1LD

6GK5204-2BC00-2AA3

6GK5204-2BC10-2AA3



6GK5206-1BC10-2AA3

X206-1LD

6GK5206-1BC00-2AA3