beautypg.com

Siemens Industrial Ethernet Switches SCALANCE X-200 User Manual

Page 193

background image

Configuration / diagnostics using remote mechanisms

6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI)

SCALANCE X-200
Operating Instructions, 12/2011, A5E00349864-19

193

Settings for IE Switches X-200

Agent Enabled Features
E-Mail

Enables/disables E-mail functionality.
DHCP

Enables/disables the IE Switch X-200 searching for a DHCP server in the network when it

starts up and configuring its IP parameters according to the data supplied by this server.
TELNET

Enables/disables the availability of the IE Switch X-200 over TELNET.
SSH

Enables / disables the SSH protocol.
Agent IP Configuration
IP Address
The IP address of the IE Switch X-200. If you make a change here, the WBM loses the

connection to the IE Switch X-200. Enter the new address in the Internet browser to

reestablish the connection.
Subnet Mask
Here, you enter the subnet mask of the IE Switch X-200.
Default gateway
If the PC with the Internet browser is not in the same subnet as the IE Switch X-200, you

must enter the IP address of the default gateway here.

Syntax of the Command Line Interface

Table 6- 14 Agent Configuration - CLI\AGENT>

Command

Description

Comment

info

Displays information on the agent settings.

ttimeout [E ¦ D ¦ Timeout]

Enable, disable or specify the TELNET

timeout. When specifying the value, a range of

60 to 600 seconds is possible.

Administrator only.

mail [E ¦ D]

Enables/disables the mailing function.

Administrator only.

ping [-c number]
[-s length]

Sends a number of packets to the specified IP

address. If the parameters for number and

length are omitted, an IE switch sends ten

packets each with a length of 128 bytes.
Example:
ping -c 5 -s 256 192.168.1.1
Five packets with a length of 256 bytes are

sent to IP address 192.168.1.1.

-

wbmtime [minutes]

Displays or specifies the time limit after which a

WBM connection is reset. A maximum value of

999 minutes can be set. The value 0 disables

the time limit.

Administrator only.