Configuration / diagnostics using remote mechanisms
6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI)
SCALANCE X-200
208
Operating Instructions, 12/2011, A5E00349864-19
SMTP Server IP Port
The IP port over which the mail is sent. If necessary, you can change the default value 25 to
your own requirements in the CLI.
"From" Field
You can enter a text that appears in the "From" field of the E-mail.
Send Test E-Mail
Sends an E-mail with the selected parameters.
Syntax of the Command Line Interface
Table 6- 21 Agent E-Mail Configuration - CLI\AGENT\EMAIL>
Command
Description
Comment
info
Shows the E-mail configuration.
mail [E ¦ D]
Enables/disables the mailing
function.
Administrator only.
smtp [IP address] [:port]
Specifies the IP address and the
port number of the SMTP
server.
Administrator only.
from [address]
Specifies a text that will be
entered in the "From" field of the
E-mail.
Administrator only.
email [E-mail address]
Specifies the address to which
an IE switch sends an E-mail.
This address can be up to a
maximum of 50 characters long.
Administrator only.
testmail
Administrator only.