Syntax of the Command Line Interface

Table 6- 12 Ring Redundancy - CLI\X200\REDUND>

Command

Description

Comment

info

Displays information on the redundancy

modules.

mode [A | AM | C | E | D]

Sets the redundancy mode:
A - Automatic Redundancy Detection

AM - MRP Manager(Auto)/Client

C - MRP Client

E - HSR Manager

D - HSR Client

Administrator only.

static [n-m]

Specifies the static (fixed) ring port.
Note:

Only for the "HSR Manager" and "HSR-

Client" modes:

Specifies the static (fixed) ring port in the

range n-m.

Administrator only.

isolated [n-m]

Specifies the isolated ring port.
Note:

Only for the "HSR Manager" and "HSR-

Client" modes:

Specifies the static (fixed) ring port in the

range n-m.

Administrator only.

rports [n-m | n-m]

Specifies the two ring ports in the range n-m. Administrator only.

clear

Resets all redundancy counters to the

original setting.

Administrator only.

redund [E ¦ D]

Enables / disables ring redundancy.