Siemens Industrial Ethernet Switches SCALANCE X-200 User Manual
Page 167
Configuration / diagnostics using remote mechanisms
6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI)
SCALANCE X-200
Operating Instructions, 12/2011, A5E00349864-19
167
● NOT PRESENT
There is no C-PLUG inserted in the IE Switch X-200.
● EMPTY
The inserted C-PLUG is empty.
C-PLUG Device Group
Indicates the SIMATIC NET product line that previously operated with the C-PLUG.
C-PLUG Device Type
Indicates the device type within the product line that previously operated with the C-PLUG.
Configuration Revision
Indicates the version of the configuration structure. This information relates to the
configuration options supported by the IE Switch X-200. This does not relate to the actual
hardware configuration. This information does not change if you add or remove modules or
extenders. The information can, however, change if you update the firmware.
File System
Shows the type of C-PLUG file system.
File System Size
Shows the maximum storage capacity of the C-PLUG file system.
File System Usage
Shows the storage space being utilized in the C-PLUG file system.
C-PLUG Info String
Displays information on the device that used the C-PLUG previously, for example order
number, type designation, version of hardware and software.
NOTICE
If an empty C-PLUG in is inserted in an IE Switch X-200, the next time the device starts up,
the configuration stored internally on the basic device is transferred to the C-PLUG.
If you operated an IE Switch X-200 with a C-PLUG inserted, the configuration stored
internally on the basic device is no longer modified.
During ongoing operation, changes to the configuration data are stored only on the C-
PLUG.
If you remove the C-PLUG later, the configuration stored internally on the basic device
becomes valid again. This restores the configuration status prior to inserting the C-PLUG.
Modify C-PLUG, Modify button
If you are logged on as administrator, you can make settings here.