Siemens Industrial Ethernet Switches SCALANCE X-200 User Manual
Page 241
Configuration / diagnostics using remote mechanisms
6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI)
SCALANCE X-200
Operating Instructions, 12/2011, A5E00349864-19
241
Variable
Access rights
Description
snX200FaultState
Read and write
Displays the error status of the device. Possible values:
1 No error
2 Error
snX200FaultValue
Read only
Errors are assigned an ascending index according to the order in
which they occur. This 4-byte variable specifies the index.
snX200RmState
Read only
Indicates whether the redundancy manager is active or passive.
Possible values:
1 The redundancy manager is passive. The IE Switch X-200 is
operating as redundancy manager and has opened the ring. In
other words, the bus with the IE Switches X-200 connected to it is
operating correctly. The "Passive" status is also shown when the
redundancy manager mode is disabled.
2 The redundancy manager is active. The IE Switch X-200 is
operating as redundancy manager and has closed the ring. In
other words, the bus with the IE Switches X-200 connected to it is
interrupted (fault). The redundancy manager switches through the
connection between the ring ports and thus restores a functioning
bus configuration.
snX200RmStateChanges
Read only
Indicates how often the redundancy manager was switched to
"active".
snBootStrapVersion
Read only
The firmware version of the bootloader in the format major.minor.
snHwVersion
Read only
The hardware version of the system in the format major.minor.
snInfoSerialNr
Read only
The serial number of the product.
snMacAddressBase
Read only
The MAC address of the IE Switch X-200.
snSwVersion
Read only
The software version of the system.
snInfoMLFB
Read only
The MLFB number of the device.
snX200PowerSupplyState
Read only
State of the redundant power supply:
1 Redundant supply
2 No redundant supply
Note:
The following devices do not have a redundant power supply:
- SCALANCE X204 IRT PRO
- SCALANCE X202-2P IRT
- SCALANCE X201-3P IRT
- SCALANCE X201-3P IRT PRO
SnX200RmMode
Read only
The redundancy manager mode
1 The IE Switch X-200 is redundancy manager.
2 The IE Switch X-200 is not redundancy manager.