beautypg.com

6 the "system save & load http" wbm menu – Siemens Industrial Ethernet Switches SCALANCE X-200 User Manual

Page 172

background image

Configuration / diagnostics using remote mechanisms

6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI)

SCALANCE X-200

172

Operating Instructions, 12/2011, A5E00349864-19

6.3.5.6

The "System Save & Load HTTP" WBM menu

System Save & Load HTTP

The WBM allows you to store configuration information in an external file on your client PC

or to load such data from an external file from the PC to the IE Switch X-200.
You can also load new firmware from a file located on your client PC. You can make the

entries required for this on the page of the System Save & Load HTTP menu.

Figure 6-12 "System Save and Load via HTTP" dialog

Configuration File

Name and possibly also folder path of the configuration file that you want to load on the IE

Switch X-200 or where you want to store the current configuration information.

Note

When a configuration file is downloaded, the device type is not checked.

Event Log File

By clicking "Save", you can save the event table (event log file) on the local computer.