Page 156

background image

Configuration / diagnostics using remote mechanisms

6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI)

SCALANCE X-200

156

Operating Instructions, 12/2011, A5E00349864-19

6.3

Configuration using Web Based Management (WBM) and

Command Line Interface (CLI)

Introduction

To make the best possible use of the technical possibilities of the IE switches, you can adapt

the configuration of the device to the concrete situation in which it is used. There are two

ways of configuring an IE switch:
● With the Command Line Interface, you can configure IE switches via Telnet or SSH (an

Ethernet connection is necessary). You can enable or disable Telnet or SSH using Web

Based Management.

● Web Based Management accesses the configuration of an IE switch over a Web

browser. An Ethernet connection to the IE switch is necessary.

NOTICE

Depending on the selected configuration method, the following mechanisms are

integrated to prevent unauthorized access to an IE switch:

CLI via TELNET or SSH

A CLI session is interrupted automatically if no input is made for more than five

minutes. This value can be assigned using the CLI (up to 600 s). The automatic

interruption of a CLI session can also be disabled with CLI.

Web Based Management

There is an automatic logout after 5 minutes; you can, however, also log out

manually using a "Logout" button on the user interface located in the header of Web

Based Management. Exiting the browser does does not close the session. If the

browser is started again within these 5 minutes, the session continues to be used.

Note
All the configuration changes are adopted in the flash memory after approximately 1 minute

or after a warm restart. You should therefore run the "Restart" command in the command

line interface or in Web Based Management before turning off the device. You can then be

certain that all the configuration changes have been saved.

Note
To use SNMP Management, RMON, and traps, you require a network management station.

This does not ship with IE switches.