Configuration / diagnostics using remote mechanisms
6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI)
SCALANCE X-200
174
Operating Instructions, 12/2011, A5E00349864-19
6.3.5.7
The "System Save & Load TFTP" WBM menu
System Save & Load TFTP
The WBM allows you to store configuration information in an external file on a TFTP server
or to load such data from an external file from the TFTP server to the IE Switch X-200.
You can also load new firmware from a file located on the TFTP server. You can make the
entries required for this on the page of the System Save & Load TFTP menu.
Figure 6-13 "System Save and Load via TFTP" dialog
TFTP Server IP Address
The IP address of the TFTP server with which you want to exchange data.
TFTP Server IP Port
The port of the TFTP server over which data exchange will be handled. If necessary, you
can change the default value 69 to your own requirements using the CLI.
Configuration File
Name and possibly also folder path of the configuration file (maximum 32 characters) that
you want to load on the IE Switch X-200 or where you want to store the current configuration
information.
Note
When a configuration file is downloaded, the device type is not checked.