3 grounding – Siemens Industrial Ethernet Switches SCALANCE X-200 User Manual
Page 142
Connection
5.3 Grounding
SCALANCE X-200
142
Operating Instructions, 12/2011, A5E00349864-19
5.3
Grounding
Installation on a DIN rail
The device is grounded over the DIN rail.
S7 standard rail
The device is grounded over its rear panel and the neck of the screw.
Wall mounting
The device is grounded by the securing screw in the unpainted hole.
Please note that X-200 IE switches must be grounded over one securing screw with
minimum resistance.
If an IE Switch X-200 is mounted on a non-conducting base, a grounding cable must be
installed. The grounding cable is not supplied with the device. Connect the paint-free surface
of the device to the nearest grounding point using the grounding cable.