2 scalance x216 tp ports – Siemens Industrial Ethernet Switches SCALANCE X-200 User Manual
Page 45
Product properties
3.7 SCALANCE X216
SCALANCE X-200
Operating Instructions, 12/2011, A5E00349864-19
45
3.7.2
SCALANCE X216 TP ports
Connector pinout
On the SCALANCE X216, the TP ports are implemented as RJ-45 jacks with MDI-X
assignment (Medium Dependent Interface–Autocrossover) of a network component.
Figure 3-8
RJ-45 jack
Table 3- 7
Pin assignment
Pin number
Assignment
Pin 8
n. c.
Pin 7
n. c.
Pin 6
TD-
Pin 5
n. c.
Pin 4
n. c.
Pin 3
TD+
Pin 2
RD-
Pin 1
RD+
NOTICE
TP cords or TP-XP cords with a maximum length of 10 m can be connected to the RJ-45
TP port.
With the IE FC cables and IE FC RJ-45 plug 180, an overall cable length of up to 100 m is
permitted between two devices depending on the cable type.