Technical specifications – Siemens Industrial Ethernet Switches SCALANCE X-200 User Manual
Page 277
Technical specifications
SCALANCE X-200
Operating Instructions, 12/2011, A5E00349864-19
277
Table 10- 3 Electrical data
Device type
SCALANCE
Power supply
2 x 12 ... 24 VDC
(10 ... 30 VDC)
SELV (Safety Extra
Low Voltage)
Power loss at 12 VDC Current consumption
at rated voltage
Overcurrent protection at
input
Non-replaceable fuse (F)
X204-2TS
+
6.60 W
0.6 A
3.0 A / 32 V
Device type
SCALANCE
Power supply
2 x 24 VDC
(18 ... 32 VDC)
SELV (Safety Extra
Low Voltage)
Power loss at 24 VDC Current consumption
at rated voltage
Overcurrent protection at
input
PTC resettable fuse
XF204
+
2.64 W
110 mA
1.1 A / 33 V
X208
+
3.84 W
160 mA
0.6 A / 60 V
XF208
+
3.12 W
130 mA
1.1 A / 33 V
X216
+
5.76 W
240 mA
1.1 A / 33 V
X224
+
8.40 W
350 mA
1.1 A / 33 V
X204-2
+
6.36 W
265 mA
0.6 A / 60 V
XF204-2
+
5.28 W
220 mA
1.1 A / 33 V
X206-1
+
5.28 W
220 mA
0.6 A / 60 V
XF206-1
+
4.08 W
170 mA
1.1 A / 33 V
X212-2
+
7.92 W
330 mA
1.1 A / 33 V
X204-2LD
+
6.36 W
265 mA
0.6 A / 60 V
X206-1LD
+
5.28 W
220 mA
0.6 A / 60 V
X212-2LD
+
7.92 W
330 mA
1.1 A / 33 V
X202-2IRT
+
6.0 W
300 mA
0.6 A / 60 V
X204IRT
+
4.8 W
200 mA
0.6 A / 60 V
XF204IRT
+
4.8 W
200 mA
0.6 A / 60 V
X204 IRT PRO
+
4.8 W
200 mA
0.6 A / 60 V
X202-2P IRT PRO
+
7.2 W
300 mA
1.1 A / 33 V
X201-3P IRT PRO
+
7.2 W
300 mA
1.1 A / 33 V
X202-2P IRT
+
7.2 W
300 mA
1.1 A / 33 V
X201-3P IRT
+
8.4 W
350 mA
1.1 A / 33 V
X200-4P IRT
+
9.6 W
400 mA
1.1 A / 33 V