Configuration / diagnostics using remote mechanisms
6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI)
SCALANCE X-200
Operating Instructions, 12/2011, A5E00349864-19
205
You can configure the reaction of the IE Switch X-200 to the following events:
Cold/Warm Start
The IE Switch X-200 was turned on or reset by the user.
Link Change
A port has failed or data traffic is being handled again over a port that had previously failed.
Authentication Failure
There was an SNMP or Web Based Management access with a bad password or
inadequate access rights (refer also to the section "Agent SNMP Configuration").
Power Change
This event occurs only when the power supply line 1 and line 2 is monitored. It indicates that
there was a change to line 1 or line 2.
Fault State Change
The fault status has changed. The fault status can relate to the activated port monitoring, the
response of the signaling contact or the power supply monitoring.
Redundancy Event
A redundancy event is triggered:
● When the redundant connection is opened or closed
● When a second ring manager is identified.
Loop detection
A loop was detected in the network.
Standby Event (relevant for IRT switches only)
A standby event is triggered:
● When the standby connection is opened or closed
● When the standby partner is lost or returns.
Signaling Contact Control
With this drop-down list, you can specify how the signaling contact works:
● conventional
Default setting for the signaling contact. An error/fault is displayed by the fault LED and
the signaling contact opens. When the error/fault state no longer exists, the fault LED
goes off and the signaling contact closes.
● aligned
The way the signaling contact works depends on the error/fault that has occurred. The
signaling contact can be opened or closed as required by user actions.
Close Signaling Contact
Select this check box if you want to close the signaling contact.
Note
The setting of the "Close Signaling Contact" check box is only effective if the "aligned"
setting was selected in the "Signaling Contact Control" drop-down list.