2 scalance x201-3p irt pro tp interfaces – Siemens Industrial Ethernet Switches SCALANCE X-200 User Manual
Page 103
Product properties
3.22 SCALANCE X201-3P IRT PRO
SCALANCE X-200
Operating Instructions, 12/2011, A5E00349864-19
103
3.22.2
SCALANCE X201-3P IRT PRO TP interfaces
Connector pinout
On the SCALANCE X201-3P IRT PRO, the TP interface is implemented as RJ-45 ports with
MDI-X assignment (Medium Dependent Interface Crossover) of a network component.
Figure 3-38 RJ-45 jack
Table 3- 22 Pin assignment
Pin number
Assignment
Pin 8
n. c.
Pin 7
n. c.
Pin 6
TD-
Pin 5
n. c.
Pin 4
n. c.
Pin 3
TD+
Pin 2
RD-
Pin 1
RD+
NOTICE
TP cords or TP-XP cords with a maximum length of 10 m can be connected to the RJ-45
TP port.
With the IE FC cables and IE RJ45 Plug PRO 180, an overall cable length of a maximum of
100 m is permitted between two devices depending on the cable type.