beautypg.com

Siemens Industrial Ethernet Switches SCALANCE X-200 User Manual

Page 175

background image

Configuration / diagnostics using remote mechanisms

6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI)

SCALANCE X-200
Operating Instructions, 12/2011, A5E00349864-19

175

Event Log File

By clicking "Save", you can save the event table (event log file) on the local computer.
Firmware File

Name and possibly also folder path of the file (maximum 32 characters) from which you want

to load the new firmware.

NOTICE

If firmware is loaded that is older than the firmware on the device, you will have to reset the

device to the factory defaults after loading the firmware.

If the firmware of an IE Switch X-200 is updated, make sure that the firmware in use is

compatible with the relevant device.
If incompatible firmware is loaded on the device, it will no longer be possible to operate the

device. In this case, compatible firmware will have to be loaded again with the boot loader.
You should therefore remember the following restrictions:

SCALANCE X200-4P IRT, X201-3P IRT and X202-2P IRT are compatible with firmware

X200IRT V2.1 or later.

SCALANCE X202-2P IRT PRO and X204P IRT PRO are compatible with firmware

X200IRT V3.1 or later.

SCALANCE XF204IRT is compatible with firmware X200IRT V4.1 or later.

SCALANCE X201-3P IRT PRO is compatible with firmware X200IRT V4.5 or later.

SCALANCE XF204, XF204-2, XF206-1, XF208 are compatible with firmware X200 V4.1

or later.

SCALANCE X204-2TS is compatible with firmware X200 V4.3 or later.

SSL Private Key File

Name of the file that contains the private key for SSL.
SSL Certificate File

Name of the file that contains the certificate for SSL

Note
The private key and the certificate for SSL are required to allow the user to communicate via

a secure connection with the Web server on the IE Switch X-200.
The files must be available in PEM format.