PROFINET IO functionality

8.2 Settings in HW Config

SCALANCE X-200
Operating Instructions, 12/2011, A5E00349864-19

249

8.2

Settings in HW Config

8.2.1

Configuring alarms

Procedure

1. Open the dialog with the general settings. In this dialog, you will find settings that apply to

the entire device.

2. To open the dialog, select the device whose settings you want to change. In the lower

half of the station window, there is a detailed view of the selected device.

3. Double-click on slot 0 to open the properties dialog of the PROFINET interface. As an

alternative, the properties dialog can also be opened by right-clicking on slot 0 and

selecting the "Object Properties" entry from the context menu.

4. Then select the "Parameters" tab. Here, you can make the following settings:
Redundant power supply

Not monitored

The failure of one of the two power supplies does not cause an alarm to be generated.

Monitored

The failure of one of the two power supplies causes an alarm.

C-PLUG

Not monitored

No alarm results from a C-PLUG error.

Monitored

A C-PLUG error causes an alarm.