Configuration / diagnostics using remote mechanisms

6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI)

SCALANCE X-200

206

Operating Instructions, 12/2011, A5E00349864-19

Syntax of the Command Line Interface

Table 6- 20 Agent Event Configuration - CLI\AGENT\EVENT>

Command

Description

Comment

info

Shows the current event configuration.

scontrol [C|A].

Selects how the signaling contact works:

Conventional

An error/fault is displayed by the LED and
the signaling contact opens.

Aligned

The signaling contact can be opened or
closed as required regardless of a
fault/error.

Administrator only.

sclose [yes|no]

Switches the signaling contact, if this in

"aligned" mode:

Yes

The contact is closed.

No:

The contact is opened

Administrator only.

Specifies how an IE switch reacts to system

events. You can enter the following values for

the parameter:
CW

Cold/Warm Start

LC

Link Change

AF

Authentication

Failure

PM

Power M12

Change

FC

Fault State Change

RD

Redundancy Event

SB

Standby Event

setec

LD

Loop Detection

Administrator only.

If an event is specified, the configured

actions are formed for each event.
The three parameters or configure

the reactions of the IE switch in the order:

E-mail

Trap

Entry in the log table

Example: If you only want to send an E-mail

when there is a Link Change, enter the

following command:

setec LC E D D