Configuration / diagnostics using remote mechanisms
6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI)
SCALANCE X-200
206
Operating Instructions, 12/2011, A5E00349864-19
Syntax of the Command Line Interface
Table 6- 20 Agent Event Configuration - CLI\AGENT\EVENT>
Command
Description
Comment
info
Shows the current event configuration.
scontrol [C|A].
Selects how the signaling contact works:
Conventional
An error/fault is displayed by the LED and
the signaling contact opens.
Aligned
The signaling contact can be opened or
closed as required regardless of a
fault/error.
Administrator only.
sclose [yes|no]
Switches the signaling contact, if this in
"aligned" mode:
Yes
The contact is closed.
No:
The contact is opened
Administrator only.
Specifies how an IE switch reacts to system
events. You can enter the following values for
the
CW
Cold/Warm Start
LC
Link Change
AF
Authentication
Failure
PM
Power M12
Change
FC
Fault State Change
RD
Redundancy Event
SB
Standby Event
setec
LD
Loop Detection
Administrator only.
If an event is specified, the configured
actions are formed for each event.
The three parameters
the reactions of the IE switch in the order:
Trap
Entry in the log table
Example: If you only want to send an E-mail
when there is a Link Change, enter the
following command:
setec LC E D D