beautypg.com

Siemens Industrial Ethernet Switches SCALANCE X-200 User Manual

Page 184

background image

Configuration / diagnostics using remote mechanisms

6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI)

SCALANCE X-200

184

Operating Instructions, 12/2011, A5E00349864-19

Ring Redundancy Manager

Here you can choose whether the "active" status of the redundancy manager triggers an

error.
Standby Manager (only SCALANCE X200IRT)

Here, you can choose whether the "master" status and "passive" or "slave" and "active" or

partner not found triggers an error.
Enable Link Down Monitoring

Error message when the status of the port is "Link down". Here, you can enable/disable

monitoring of the link status for the individual ports.
Enable Link Up Monitoring

Error message when the status of the port is "Link up". Here, you can enable/disable

monitoring of the link status for the individual ports.

Note
With the default setting as supplied, no port is monitored; in other words, the fault mask is

empty.
As default, the power supply is also not monitored.

Syntax of the Command Line Interface

Table 6- 11 Fault Mask - CLI\X200>

Command

Description

Comment

info

Displays information on the "X-200" menu item.

fault

Displays the fault status.

downmask <1-n> Specifies a port mask for the ports for which the

monitoring of a link down event is enabled.

Administrator only.

upmask <1-n>

Specifies a port mask for the ports for which the

monitoring of a link up event is enabled.

Administrator only.

others

Specifies the fault mask for:

P - power mask

Administrator only.