beautypg.com

39 the "statistics packet error" wbm menu – Siemens Industrial Ethernet Switches SCALANCE X-200 User Manual

Page 236

background image

Configuration / diagnostics using remote mechanisms

6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI)

SCALANCE X-200

236

Operating Instructions, 12/2011, A5E00349864-19

6.3.5.39

The "Statistics Packet Error" WBM menu

Statistics Packet Error - Counting and evaluation of transmission errors

This dialog displays information on any errors that may have occurred and allows

diagnostics for the port on which the error occurred. You can reset the error counters with

the "Reset Counters" button.
If you click on an entry in the Port column, the Statistics Packet Error Graphic is displayed for

the selected port. You then see a graphical representation of the counter value.

Figure 6-44 "Statistics Packet Error" dialog

The following errors can be detected:
CRC
Packets with a valid length but bad checksum.
Undersize
Packets too short with valid checksum.
Oversize
Packets too long with valid checksum.
Jabbers
Packets too long without valid checksum.
Collisions