FIGURE A-10 Library and Rack Clearances
1. 60.9 cm (2 ft) minimum service clearance behind the library or rack
2. 81.0 cm (31.9 in.) depth of Base Module from front mounting plane to back of tape drives
3. 76.2 cm
(30.0 in.) depth of original design Base Module
71.4 cm
(28.1 in.) depth of EZ install Base Module (with optional extensions, depths up to 94 cm [37
in.])
4. 3.8 cm (1.5 in.) depth of front door, required clearance
5. 5.3 cm (2.1 in.) depth of front door and unique latch hardware
6. 24.1 cm (9.5 in.) front door opening clearance
7. 60.9 cm (2 ft) minimum front service clearance