Troubleshooting, Information included in, Troubleshooting 257 – Sun Microsystems StorageTek Modular Library System SL500 User Manual

Page 289: Table 7-1

background image

Troubleshooting

96116 • Revision: KA

Chapter 7 SL Console Diagnostics and Utilities 257

Troubleshooting

Before you run diagnostic tests, check the following areas of the library using the

troubleshooting tips in the following table:

TABLE 7-1 Troubleshooting Table

Problem

What to do

Service Required

(amber) LED is

constantly on.

Perform the following procedure:
Using the SL Console, check the health of the library and the attached

devices (drives, CAP, and robots). See

“StorageTek Library Console”

on page 27

for more details about operations.

To perform a health check:
1. Log in to the SL Console application.
2. Access the System Detail module, View > System Detail.
3. Check the device tree for the following indicators:

Device Healthy

Device Error

The Status (for example, online/offline) and Statistics (for example,

uptime, downtime, errors and warnings) tabs provide more

information on the health of the library and devices.
Other checks:

Make sure that cartridges are fully seated and properly oriented in their
storage cells.

Inspect the X table for any foreign objects or debris; remove them if found.

Library does not power-

on. The SL Console

does not display any

messages.

1. Check that the library power switch is in the ON position.
2. Check all power cord connections.
3. Replace the power cord.
4. Make sure that there is power to the outlet.

CAP open LED is on

and blinking.

Open the CAP and make sure that the cartridges in the CAP cells are

properly seated.

The client computer

cannot communicate

with the library or tape

drives.

Make sure that cables are securely attached to their connectors on the

rear of the library, tape drives, and client computer.

The SL Console does

not display modified

data or information

remains static.

Check the SL Console Heartbeat icon.