beautypg.com

P821 spike filter, P822 narrow echo filter, P823 reform echo – Siemens sitrans LU01 User Manual

Page 80

background image

Page 74

SITRANS LU01 – INSTRUCTION MANUAL

7ML19985BE02

Pa

ra

m

e

te

rs

P821 Spike Filter

Dampens spikes in the echo profile to reduce false readings.

Use P821 if interference spikes are on the long shot Echo Profile display.

P822 Narrow Echo Filter

Filters out echoes of a specific width. Enter width of false echo in msec.

Use this for transducer acoustic beam interference (e.g. ladder rungs). Enter the width of
false echoes (in ms) to be removed from the long shot Echo Profile. When a value is keyed
in, the nearest acceptable value is entered.

P823 Reform Echo

Smoothes jagged peaks in the echo profile. Reforms fragmented echoes into one.

Values

0

Off

1

* On

Related

P817 Profile Pointer Time

P818 Profile Pointer Distance

P819 Profile Pointer Amplitude

P820 Algorithm

P822 Narrow Echo Filter

P823 Reform Echo

P825 Echo Marker Trigger

Values

0 = OFF (preset)
greater = wider

Related

P817 Profile Pointer Time

P818 Profile Pointer Distance

P819 Profile Pointer Amplitude

P820 Algorithm

P821 Spike Filter

P823 Reform Echo

P825 Echo Marker Trigger

Values

0 = OFF (preset)
greater = wider

Related

P002 Material

P817 Profile Pointer Time

P818 Profile Pointer Distance

P819 Profile Pointer Amplitude

P820 Algorithm

P821 Spike Filter

P822 Narrow Echo Filter

P825 Echo Marker Trigger