Transducer, Options, Cable – Siemens sitrans LU01 User Manual
Page 13: Transducer options cable
7ML19985BE02
SITRANS LU01 – INSTRUCTION MANUAL
Page 7
mm
mmm
Spec
if
icat
ions
Transducer
Compatible Models
• STH and Echomax
®
series
• Refer to the associated instruction manual.
Options
Temperature Sensor
• TS-3
SmartLinx Modules
• Supported protocols: PROFIBUS DP
Allen-Bradley®
1
Remote I/O
Modbus® RTU
DeviceNet
TM
Dolphin Plus
• Windows
®
-compatible configuration software connected to the unit via infrared
Comverter link
Refer to associated product documentation.
Cable
Transducer
• RG-62 A/U (or equivalent), 365 m (1,200 ft) max.
See transducer instructions for short extensions (in grounded metal conduit, separate
from other wiring)
mA Output
• Belden 8760, shielded / twisted pair, 18 AWG (0.75 mm
2
) or equivalent or Belden 9552,
shielded / two twisted pair, 18 AWG (0.75 mm2)
• maximum separation 1,500 m (5,000 ft)
Synchronisation
• Belden 8760, shielded / twisted pair, 18 AWG (0.75 mm
2
) or equivalent
Relays
• No shielded cable necessary
Temperature sensor
• Belden 8760 shielded / twisted pair, 18 AWG (0.75 mm
2
) or equivalent
• 365 m (1,200 ft) per TS-3 maximum
RJ11 Link
• No shielded cable necessary
• maximum length 3 m (10 ft)
1.
Allen-Bradley is a registered trademark of Rockwell Automation. Modbus is a
registered trademark of Schneider Electric. DeviceNet is a trademark of ODVA
(Open DeviceNet Vendor Association).