P791 Bus Error
Indicates if an error condition is occuring on the bus.
P792 Bus Error Count
A count that increments by 1 each time a bus error (P791) is reported..
P794 SmartLinx Module Type
This parameter is used to identify the module type when SmartLinx is used. If you are not
using SmartLinx, this parameter is not functional. Please see the associated SmartLinx
instruction manual for a full description of this parameter.
P795 SmartLinx Protocol
This parameter is used to identify the protocol when SmartLinx is used. If you are not
using SmartLinx, this parameter is not functional. Please see the associated SmartLinx
instruction manual for a full description of this parameter.
Echo Processing (P800 to P807)
P800 Near Blanking
The space near the transducer face which cannot be measured.
Values
0
*
No error
Any
other
value
Error code; refer to SmartLinx module documentation for
explanation of error code.
Related
•
P790 Hardware Error
Values
Range: 0* to 9999
Error count; provide this number to your Siemens Milltronics repre-
sentative for troubleshooting.
Related
•
P790 Hardware Error
Values
Range: 0.000 to 9999
Preset: transducer
dependent
Altered by
•
P004 Transducer
Related
•
P006 Empty
•
P007 Span
•
P833 TVT Start Min