background image

Page 70

SITRANS LU01 – INSTRUCTION MANUAL

7ML19985BE02

Pa

ra

m

e

te

rs

P806 Echo Strength

Displays the strength (in dB above 1 μV rms) of the echo which was selected as the

measurement echo.

P807 Noise

Displays the average and peak ambient noise (in dB above 1 μV rms) being processed.

The noise level is a combination of transient acoustic noise and electrical noise (induced
into the transducer cable or receiving circuitry). See

Noise Problems in the

Troubleshooting Section on page 99.

Advanced Echo Processing (P810 to P825)

Anatomy of an Echo Profile

The relevant parts of an echo profile are listed here. These are visible in either Dolphin
Plus or an oscilloscope.

Values

Format: 0 to 99 (view only)

Values

Format: x:y (view only)
x = average (-99 to 99)
y = peak (-99 to 99)

Note:

The following parameters are for authorized Siemens Milltronics Service

personnel or technicians familiar with Siemens Milltronics echo processing
techniques.

echo lock window

echo marker

selected echo

echo profile

TVT curve