Table 10. error beep codes generated by intel – Intel SERVER SYSTEM SR2500AL User Manual
Page 143
Intel® Server System SR2500AL User’s Guide
121
In addition to the beep codes above, additional beep codes are provided if an Intel
®
Remote Management Module is installed. The Intel
®
Remote Management Module
provides the following additional beep codes.
Table 10. Error Beep Codes Generated by Intel
®
Remote Management
Module
Number of
Beeps
Reason for Beeps and Action to Take
1
Control panel CMOS clear has been initiated.
1-5-1-1
Processor failure. Reseat or replace the failed processor.
1-5-2-1
No processor is installed or the CPU 1 socket is empty. Reseat or replace
the failed processor.
1-5-2-3
Processor configuration error or CPU 1 socket is empty. Reseat or replace
the failed processor. In a two-processor system, make sure the processors
are identical.
1-5-2-4
Front-side bus select configuration error.
1-5-4-2
DC power unexpectedly lost.
1-5-4-3
Chipset control failure.
1-5-4-4
Power control failure.