beautypg.com

Grizzly G0623X3 User Manual

Page 35

background image

Model G0623X/G0623X3 (Mfg. Since 5/12)

-33-

to test run the saw:

1. put on safety glasses, make sure any bystand-

ers are out of the way, and that all tools have
been removed from the saw.

2. push in, then rotate both stop buttons

clockwise until they pop out. this resets the
switch so the machine can be started.

3. press the oN button. the blades should

startup and run smoothly without any prob-
lems. If any problems occur, immediately
press the STOP button.

4. press the stop button. as the main blade

comes to a stop, watch the direction that it
spins.

— the main blade should spin clockwise if you

are standing at the front of the machine. if
this is true, continue to

step 5.

—if the main blade rotates counterclock-

wise, disconnect the saw from power and
exchange wires r & t in the power con-
nection box to change the motor direction
(model g0623X3 only). after exchanging
the wires and closing the power connection
box, connect the saw to power, and repeat

steps 3–4.

5. make sure the stop button is pushed in,

then press the oN button.

—the saw should Not start if the disabling

feature on the stop button is working cor-
rectly. if this is true, continue to

step 6.

—if the saw does start when the stop but-

ton is pushed in, then the safety feature
on the stop button is not working cor-
rectly. Call tech support for advice before
proceeding any further with the test run or
machine operations.

6. disCoNNeCt saW from poWer!

7. move the sliding table all the way forward,

then open the orange blade guard (refer to

page 41 for details on accessing and open-
ing the blade guard). opening the blade
guard triggers the limit switch.

8. Connect the saw to the power source and

rotate the stop button clockwise so it pops
out.

9. (during this step, be prepared to immediately

press the stop button if the blades start
operating.) press the oN button.

—if the blade guard limit switch functions cor-

rectly, the machine will not start. if this is
true, continue to

step 10.

—if the machine starts during this test, the

limit switch is Not functioning correctly.
disconnect the saw from power, and call
tech support for advice before proceeding
any further with the test run or machine
operations.

10. Close the orange blade guard and move

the sliding table back to the center of the
machine.