User Electrical Lines

There is a 25-pin male connector (24 conductor) on the robot user panel on the back of
Joint 1 for user electrical lines (see

Figure 6-2

). This connector is wired directly to a 25-pin

female connector on the top of the outer link (see

Figure 6-3

). These connectors can be

used to run user electrical signals from the user panel, through the robot, and up to the
outer link.

Wire Specifications: Wire size: 0.1 mm

2

, Pin Numbers 1-24, 12 pairs, twisted in pairs as

1&2, 3&4, 5&6, ..., 23&24. Maximum current per line: 1 Amp.