beautypg.com

4 exclusions and incompatibilities, 5 maintenance, Bellows replacement – Adept i600 Cobra User Manual

Page 103: 4 exclusions and incompatibilities 8.5 maintenance

background image

Exclusions and Incompatibilities

Adept Cobra i600/i800 Robot User’s Guide, Rev G

103

8.4

Exclusions and Incompatibilities

8.5

Maintenance

Bellows Replacement

Check the bellows periodically for cracks, wear, or damage. Replace bellows (Adept P/N
04625-000) if necessary, using the procedure below.

1. Remove the lower bellows clamp ring from the bearing ring by loosening the

screw on the clamp. See

Figure 8-3

.

2. Remove the tool flange. Refer to

Section 6.2 on page 71

for the tool flange

removal procedure.

3. Remove the upper bellows clamp ring by loosening the screw on the clamp.

4. Slide the old bellows down off of the quill.

5. Install a new bellows, and reverse the steps listed above.

Table 8-3. Internally-Mounted Hand Valves

Installation considerations

The internal air line normally used to supply
the internally-mounted hand valves (Adept
Option Kit P/N 02853-000) is instead used to
provide vacuum to the bellows/outer link. One
of the passive 6 mm user air lines would need
to be used instead.

Performance considerations

The air exhausting from the
internally-mounted hand valves (Adept Option
Kit P/N 02853-000) may be of sufficient
quantity/ quality to cause the robot to exceed
Class 10 Particulate Limits.

Recommendation

For these reasons, Adept recommends
mounting hand valves externally.

This manual is related to the following products: