System Installation

24

Adept Cobra i600/i800 Robot User’s Guide, Rev G

3.2

System Cable Diagram

Figure 3-1. iCobra System Cable Diagram

Installation Procedure

Step

Step Description

Part(s)

1

Connect AIB XPANEL cable to XPANEL on Interface Panel.

A

2

Verify XUSR jumper plug is installed on XUSR connector.

B

3

Connect Front Panel cable to Front Panel and XFP connector.

C, D

4

If no T2, install XMCP jumper or T1/T2 bypass plug. Skip to 5.

E, F

4a

If you have T2, connect T1/T2 adapter cable to XMCP connector.

G, H

5

Connect user-supplied ground. See

Section 3.8 on page 34

for locations.

-

6

Connect 200-240 VAC to AC Input on Interface Panel, secure with clamp.

J

7

Connect 24 VDC to DC Input on Interface Panel. (May need AC cable.)

K, L

8

Connect null modem serial cable to Interface Panel and serial port on PC.

M

Adept Cobra
i600/i800 Robot

24 VDC, 6 A
Power Supply

200-240 VAC
10 A
single-phase

AC Power
Cable

DC Power
Cable

Front Panel
Cable

Front Panel

User-Supplied PC
running Adept ACE

T1/T2 Adapter
Cable

XMCP Jumper Plug

XMCP

XFP

XUSR

XUSR
Jumper
Plug

AIB
XPANEL
Cable

Robot Interface

Panel

XUSR for:
- User E-Stop/Safety Gate
- Muted Safety Gate
- Jumper plug required
when not used

RS-232 Null Modem Cable
for Robot to PC Connection

T1/T2 Bypass Plug

User-Supplied
Ground Wire

GND

XSLV

1

2

SmartServo

RS-232

XPANEL

AC INPUT

(200-240 VAC 1

&)

+24V

DC INPUT

(24 VDC)

XIO

GND

XSLV

1

2

SmartServo

RS-232

XPANEL

AC INPUT

(200-240 VAC 1

&)

+24V

DC INPUT

(24 VDC)

XIO

T2 Pendant (optional)

Either T1/T2 Bypass Plug or XMCP Jumper Plug
must be installed if T2 is not used

2

3

4a

A

B

E

F

G

4a

4

4

1

5

6

7

8

8

J

K

M

D

H

C

L

3

85 - 264 VAC
Universal
Input