XIO Input

Signals

The 12 input channels are arranged in two banks of six. Each bank is electrically isolated
from the other bank and optically isolated from the robot’s ground. The six inputs within
each bank share a common source/sink line.

The inputs are accessed through direct connection to the XIO connector (see

Table 4-5 on

page 43

), or through the optional XIO Termination Block. See the documentation supplied

with the Termination Block for details.

The XIO inputs cannot be used for REACTI programming, high-speed interrupts, or
vision triggers.

XIO Input Specifications

NOTE: The input current specifications are provided for reference.
Voltage sources are typically used to drive the inputs.

Table 4-6. XIO Input Specifications

Operational voltage range

0 to 30 VDC

“Off” state voltage range

0 to 3 VDC

“On” state voltage range

10 to 30 VDC

Typical threshold voltage

V

in

= 8 VDC

Operational current range

0 to 7.5 mA

“Off” state current range

0 to 0.5 mA

“On” state current range

2.5 to 7.5 mA

Typical threshold current

2.0 mA

Impedance (V

in

/I

in

)

3.9 K minimum

Current at V

in

= +24 VDC

I

in

 6 mA

Turn on response time (hardware)

Software scan rate/response time

5 µsec maximum

16 ms scan cycle/32 ms max response time

Turn off response time (hardware)

Software scan rate/response time

5 µsec maximum

16 ms scan cycle/32 ms max response time