beautypg.com

Figure 5-3, Opening and removing aib chassis, Figure 5-4 – Adept i600 Cobra User Manual

Page 66: Connectors on aib chassis

background image

Maintenance

66

Adept Cobra i600/i800 Robot User’s Guide, Rev G

8. While holding the chassis heat sink, carefully and slowly lower the chassis down

(see

Figure 5-3 on page 66

), so that enough access is available to remove the

internal cables. The chassis can be laid flat or placed to the right side of the robot
for better access.

Figure 5-3. Opening and Removing AIB Chassis

9. Disconnect the “white” amplifier cable from the amplifier connector located on

the chassis bracket. See

Figure 5-4

.

Figure 5-4. Connectors on AIB Chassis

10. Carefully disconnect the J1 cable from the J1 connector on the PMAI, by

disengaging the securing latches.

11. Carefully disconnect the J11 cable from the J11 connector on the PMAI, by

disengaging the securing latches.

12. Carefully disconnect the J27 cable from the J27 connector on the PMAI, by

disengaging the securing latches.

13. Carefully disconnect the J28 cable from the J28 connector on the PMAI, by

disengaging the securing latches.

J1

J11

J27

J28

Amplifier Connector

PMAI Board

This manual is related to the following products: