Adept Cobra i600/i800 Robot User’s Guide, Rev G

49

4.7

Connecting Customer-Supplied Safety and Power Control
Equipment

Connecting Equipment to the System

The connection of the customer-supplied safety and power control equipment to the
system is done through the XUSR and XFP connectors on the AIB XPANEL cable. Refer to

Table 4-9

for the XUSR pin-out explanations. Refer to

Table 4-10 on page 50

for the XFP

pin-out explanations. See

Figure 4-8 on page 52

for the E-Stop wiring diagram.

Table 4-9. Contacts Provided by the XUSR Connector

Pin

Pairs

Description

Comments

Shorted if

NOT Used

Voltage-Free Contacts Provided by Customer

1, 14

User E-Stop CH 1 (mushroom PB,
safety gates, etc.).

N/C contacts

Yes

2,15

User E-Stop CH 2 (same as pins 1
and 14).

N/C contacts

Yes

3,16

Not supported on Cobra i-series robot

4,17

Not supported on Cobra i-series robot

5,18

Muted Safety Gate CH 1 (causes
E-Stop in AUTOMATIC mode only).

N/C contacts

Yes

6,19

Muted Safety Gate CH 2 (same as
pins 5 and 18).

N/C contacts

Yes

Voltage-Free Contacts provided by Adept

7,20

Not supported on Cobra i-series robot

8,21

Not supported on Cobra i-series robot

9,22

Not supported on Cobra i-series robot

10,23

Not supported on Cobra i-series robot

11,12,

13, 24,

25

No connection

XUSR

Pin 1

Pin 13

Pin 14

Pin 25