beautypg.com

Xio output signals, Xio output specifications – Adept i600 Cobra User Manual

Page 46

background image

System Operation

46

Adept Cobra i600/i800 Robot User’s Guide, Rev G

XIO Output Signals

The eight digital outputs share a common, high side (sourcing) Driver IC. The Driver is
designed to supply any kind of load with one side connected to ground. It is designed for
a range of user-provided voltages from 10 to 24 VDC and each channel is capable of up to
0.7 A of current. This Driver has overtemperature protection, current limiting, and
shorted-load protection. In the event of an output short or other overcurrent situation, the
affected output of the Driver IC turns off and back on automatically to reduce the
temperature of the IC. The Driver draws power from the primary 24 VDC input to the
robot through a self-resetting polyfuse.

The outputs are accessed through direct connection to the XIO connector (see

Table 4-5

on page 43

), or through the optional XIO Termination Block. See the documentation

supplied with the XIO Termination Block for details.

XIO Output Specifications

Table 4-7. XIO Output Circuit Specifications

Parameter

Value

Power supply voltage range

See

Table 3-1 on page 29

.

Operational current range,
per channel

I

out

 700 mA

Total Current Limitation,
all channels on.

I

total

1.0 A @ 50° C ambient 

I

total

1.5 A @ 25° C ambient

On state resistance (I

out

= 0.5 A)

R

on

 0.32

@85× C

Output leakage current

I

out

 25 µA

Turn-on response time

125 µsec. max., 80 µsec typical
(hardware only)

Turn-off response time

60 µsec. max., 28 µsec typical
(hardware only)

Output voltage at inductive load
turnoff (I

out

= 0.5 A, Load = 1 mH)

(+V - 65)  V

demag

 (+V - 45)

DC short circuit current limit

0.7 A  I

LIM

 2.5 A

Peak short circuit current

I

ovpk

 4 A

This manual is related to the following products: