Dlt drive problems – HP ProLiant DL100 Series Server DL100 Series User Manual

Page 69

background image

Latest firmware indicates a defective tape, or head clogs occur regularly

Action: Replace the tape.

Other errors are occurring

Action: Replace the drive.

DLT drive problems

Server cannot write to tape

Action:

If the drive cleaning light is on, clean the drive.

NOTE:

DLT cleaning cartridges are good for only 20 uses. If the cleaning cartridge is near

that limit and the drive cleaning light is still on after running the cleaning cartridge, use a new

cleaning tape to clean the drive.

If the tape is write protected, remove the write protection. If the tape still does not work, insert
another tape into the drive to see if the original tape is faulty.

Refer to the tape drive documentation to be sure the type of tape being used is supported by the
drive.

Check each tape cartridge that has been used in the drive to verify its condition and inspect its tape
leader to verify it is not damaged and is in the correct position. After you locate any bad cartridges,

dispose of them. A working tape drive may drop its leader when using bad cartridges, indicating

that they need replacing. If bad cartridges are found, you will need to inspect the DLT drives leader

assembly.

o

To examine the cartridge take-up leader, tilt the cartridge receiver door on the front of the drive

and look inside to see that the drive leader is connected to the buckling link-hook.

o

To examine the drive take-up leader, tilt the cartridge receiver door on the front of the drive and
look inside to see that the drive leader is connected to the buckling link-hook, which should be

engaged in the leader slot.

If the drive is connected to a nonembedded controller, be sure the controller is properly seated.

DLT drive failure occurs

Action:

Be sure the power and signal cables are properly connected.

Be sure the power and signal cable connectors are not damaged.

DLT drive does not read tape

Action:

Be sure the drive is seated.

Be sure the drive is installed properly.

Troubleshooting 69