HP SureStore 4215w User Manual
Page 93

3-39
Operating the Library
Troubleshooting
L
ibrary
O
perat
io
n
DEVICE
FAILED
displays.
Hardware Error #61 (External SCSI
cables) is reported.
•
Make sure that only one SCSI device type (single-ended OR
differential) exists on the SCSI bus.
•
Verify that the library SCSI selector switch is set correctly
(either single-ended or differential).
•
Verify that the mode switch termination is set correctly.
The library’s power failed while a
cartridge was in the drive and did not
return to the drive status indicators
("ready" state) after the power came
back on.
•
Press the power switch off and then on again. (See the
caution note at the end of this table.)
•
If the power-on test is unsuccessful, switch off the power.
Call a service representative for assistance.
No display messages appear.
•
Make sure the power cord is connected.
•
Make sure the power switch is on.
•
Power cycle the library. (See the caution note at the end of
this table.)
•
If there is still no display, call a service representative for
assistance.
Problem
What to do