beautypg.com

HP SureStore 4215w User Manual

Page 88

background image

3-34

Operating the Library

Running an Internal Test

WELLNESS

TEST

Checks the general capability of the library. Requires one loaded tape cartridge,
but the drives and transport must be empty. Runs

INIT

MECHANICS

and

EXERCISE

MECH

. Each test is run one time per test loop.

FIND

PLUNGE

HOME

Runs mechanism recalibrartion, determines the reference points in the picker
travel path, and tests the picker. This test assumes that the mechanics and servo
system are functional. No tape cartridges are required.

FIND

VERT

HOME

Recalibrates the vertical position and verifies that the vertical path is clean. No
tape cartridges are required.

FIND

XLATE

HOME

Calibrates the translate position. No tape cartridges are required.

INIT

MECHANICS

Runs the

FIND

PLUNGE

HOME

,

FIND

VERTICAL

HOME

,

FIND

XLATE

HOME

,

and

INIT

ELEM

STATUS

tests. Each test is run one time per test loop.

EMPTY

DRIVES

Used by service personnel only. Do not run this test if the library contains
tape cartridges with actual file system data on them.
Moves cartridges out of
the drive mechanism and returns them to their original storage slot locations if the
locations are know, otherwise the cartridges are placed into the first available
storage slot.

EMPTY

PICKER

Used by service personnel only. Do not run this test if the library contains
tape cartridges with actual file system data on them.
Moves a tape cartridge
from the cartridge transport mechanism to its original storage slot location if the
location is know, otherwise the cartridge is placed into the first available storage
slot.

FILL

PICKER

Used by service personnel only. Do not run this test if the library contains
tape cartridges with actual file system data on them.
Moves a tape cartridge
into the cartridge transport mechanism from the first storage slot containing a
cartridge.

REWIND

MEDIA

Used by service personnel only. Do not run this test if the library contains
tape cartridges with actual file system data on them.
Rewinds the tape in the
drive(s) and opens the solenoid in the drive handle, which allows the tape to be
removed from the drive by lifting the handles. If the picker malfunctions, use this
option to get the tapes out of the drive.

CLEAR

SOFT

LOG

Sets the soft error log to zero.

CLEAR

HARD

LOG

Sets the hard error log to zero.

Test Name