Operating the Library

Setting and Viewing SCSI IDs

Setting SCSI IDs

A SCSI ID is required for the robotics controller and each drive. The default IDs are
shown in Table 3-1 on page 3-11.

The following configuration choices are available:

Table 3-2

SCSI Address Configuration Options

To change the current SCSI address settings:

1. Verify that the drive status displays (if not, press

CANCEL

until it does).

2. Press

NEXT

until

ADMIN

*

displays, then press

ENTER

.

3. Enter the three-part numerical password (see “Entering the Administration

Menu Password” on page 3-9).

4. Press

NEXT

until

SCSI

IDs

*

displays, then press

ENTER

.

5.

SET

IDs

*

displays. Press

ENTER

.

LIB

BUS

#

ID

#

or

DRV

#

BUS

#

ID

#

displays. LIB BUS # ID # stands for the

current SCSI ID of the robotics controller. DRV # BUS # ID # is the current
SCSI ID setting for the drive number and its associated bus #.

6. Press

NEXT

until the setting to change displays, then press

ENTER

.

1 2

ADMIN *

SCSI IDs *

SET IDs *

Number of

Drives

SCSI Bus Addresses Available

1

13 addresses are available on bus 1. (Drive 1 uses one address
and the library controller uses 1 address.)

2

If buses 1 and 2 are connected to separate host SCSI cards:

13 addresses are available on bus 1 for other devices.

14 addresses are available on bus 2 for other devices.

If buses 1 and 2 are daisy-chained:

12 addresses are available on the bus for other devices.