Setting scsi ids, Setting scsi ids -12, Table 3-2. scsi address configuration options -12 – HP SureStore 4215w User Manual
Page 66

3-12
Operating the Library
Setting and Viewing SCSI IDs
Setting SCSI IDs
A SCSI ID is required for the robotics controller and each drive. The default IDs are
shown in Table 3-1 on page 3-11.
The following configuration choices are available:
Table 3-2
SCSI Address Configuration Options
To change the current SCSI address settings:
1. Verify that the drive status displays (if not, press
CANCEL
until it does).
2. Press
NEXT
until
ADMIN
*
displays, then press
ENTER
.
3. Enter the three-part numerical password (see “Entering the Administration
4. Press
NEXT
until
SCSI
IDs
*
displays, then press
ENTER
.
5.
SET
IDs
*
displays. Press
ENTER
.
LIB
BUS
#
ID
#
or
DRV
#
BUS
#
ID
#
displays. LIB BUS # ID # stands for the
current SCSI ID of the robotics controller. DRV # BUS # ID # is the current
SCSI ID setting for the drive number and its associated bus #.
6. Press
NEXT
until the setting to change displays, then press
ENTER
.
1 2
→
ADMIN *
→
SCSI IDs *
→
SET IDs *
Number of
Drives
SCSI Bus Addresses Available
1
13 addresses are available on bus 1. (Drive 1 uses one address
and the library controller uses 1 address.)
2
If buses 1 and 2 are connected to separate host SCSI cards:
•
13 addresses are available on bus 1 for other devices.
•
14 addresses are available on bus 2 for other devices.
If buses 1 and 2 are daisy-chained:
•
12 addresses are available on the bus for other devices.