Operating the Library

Setting and Viewing SCSI IDs

L

ibrary

O
perat

io

n

7. The current SCSI address setting flashes. Press

NEXT

or

PREV

until the desired

address displays, then press

ENTER

.

8. Press

NEXT

until

UPDATE

IDs

NOW

displays, then press

ENTER

.

9.

IDs

SAVED

displays briefly, then one of the following messages displays:

If the new settings do not conflict with other SCSI IDs in the library,

SCSI

IDs

*

displays.

If the new settings conflict with other IDs in the library,

CONFLICT

ABORTED

displays briefly, then

SET

IDs

*

displays. Any changes entered

are lost, and previous steps must be repeated to set a new address.

If any buses are daisy chained together, make sure the SCSI IDs are different
for each device on the bus.

If a serial communications error is detected while trying to set the SCSI IDs,

DRV

CONNECT

ERR

displays, followed by

IDs

NOT

CHANGED

. Any

changes entered are lost. The

SCSI

IDs

* menu displays.

10. Press

CANCEL

three times to return to the drive status (“ready” state).

NOTE

To save new settings can be saved to flash ROM, turn the library off, then turn it
back on. This allows the settings to be recovered if the library is powered off for
more than ten days.

Do not switch off power to the library until the SCSI bus is inactive. Removing
power from a SCSI peripheral when the bus is active can result in data loss and/or
indeterminate bus states. (Check the host system manuals for information about
checking the SCSI bus status.) If the host is connected to a LAN, be sure to check
with the system administrator before shutting off power to the library.