Troubleshooting example using cli, System board diagnostic leds, Stby, f/w, and bmc leds locations – HP AD117-9003A-ED3 User Manual
Page 109
00E0 7 CPU0 Halt boot 00037 DT 04 000000000000000F
00F0 7 CPU0 Halt boot 00037 Time 2003-10-31 22:29:06
Troubleshooting Example Using CLI
This example uses the CLI and the SEL to display error message indicating that fan 2 (memory
fan) has failed.
cli>sl e
# Sev Generator/Sensor Description Event ID Data, Timestamp
---- - ---------------- ------------ ----------- --------------------------
0010 - BMC Chass cntrl 00-12:70:A3 81:03 2003-10-31 22:39:02
0020 - BMC LPC reset 00-12:70:02 2003-10-31 22:39:03
0030 - Fan 1 (PSU) OK 11-0A:07:00 2003-10-31 22:39:04
0040 - Fan 3 (CPU) OK 13-0A:07:00 2003-10-31 22:39:04
0050 - ACPI State S0 (on) FA-22:6F:00 2003-10-31 22:39:05
0060 - SFW Boot start 00-1D:0A:00 2003-10-31 22:39:05
0070 2 CPU1 Boot start 00063 DT 04 0000000000000000
0080 2 CPU1 Boot start 00063 Time 2003-10-31 22:39:05
0090 - BMC LPC reset 00-12:70:02 2003-10-31 22:39:07
00A0 - SEL Time Set Set FD-C0:03:01 2003-10-31 22:39:15
00B0 - Fan 2 (Mem) Fail (crit) 12-0A:07:02 2003-10-31 22:39:24
00C0 - BMC Chass cntrl 00-12:70:A3 00:E2 2003-10-31 22:39:31
00D0 - ACPI State S5 (off) FA-22:6F:05 2003-10-31 22:39:32
System Board Diagnostic LEDs
There are three additional LEDs that can help when troubleshooting the server. These LEDs are
located on the system board close to the back of the server and can be viewed through the small
cooling holes in the server case. See
for the STBY, F/W, and BMC LED locations.
Figure 5-3 STBY, F/W, and BMC LEDs Locations
details the LED states of the STBY, F/W, and BMC LEDs on the system board.
System Board Diagnostic LEDs