beautypg.com

Performing a sonet tributary scan, Performing a sonet tributary scan 80 – HP OMNIBER 718 HP 37718A User Manual

Page 90

background image

80

Making Measurements

Performing a SONET Tributary Scan

Performing a SONET Tributary Scan

Description

Tributary Scan tests each tributary for error free operation and no
occurrence of Pattern Loss. A failure is indicated by highlighting the
tributary in which the failure occurred. The

,

mapping setup determines the tributary structure.

The HP 37718A will configure the Transmitter to the Receiver and the
PATTERN is forced to the payload it will fill.

TIP:

The SONET Tributary Scan display can be logged to the chosen logging
device. See "Logging on Demand " page 110.

HOW TO:

1

Set up the transmit and receive SONET interfaces and payload as
required. See "Setting SONET Transmit Interface " page 4 and

"Setting SONET Receive Interface " page 17.

2

Choose the required BIT ERROR THRESHOLD.
This determines the error rate above which a failure is declared.

3

Choose the required TEST TIMING.
The value you choose is the test time for each individual tributary and
not the total test time.
For example, 28 VT-1.5 tributaries in an STS-1 SPE - the time taken
to complete the Tributary Scan will be 28 X TEST TIMING choice.

TRANSMIT

SONET

MAIN SETTINGS