View the results – HP OMNIBER 718 HP 37718A User Manual
Page 106
96
Making Measurements
Measuring Jitter Transfer
HOW TO:
View the Results
1
Choose the results FORMAT.
If
is chosen, a plot of the jitter transfer results against the
ITU-T mask is displayed.
If
is chosen, the results from which the graph is constructed are
displayed: Point number, Frequency, Mask amplitude (dB), Jitter Gain
(dB), Result.
If applicable, results 13 through 55 can be viewed on pages 2 through
5.
2
If
is chosen, choose the SCALE required.
provides a vertical axis range of +5 to -60 dB and is
recommended for viewing the high frequency portion of the graph.
This allows a clearer view of the difference between the actual result
and the ITU-T pass mask.
provides a vertical axis range of +3 to -3 dB and is
recommended for viewing the low frequency portion of the graph. This
allows a clearer view of the difference between the actual result and
the ITU-T pass mask.
3
If you wish to log the jitter tolerance results to a printer, See “Logging
Jitter Transfer Results” page 114.
GRAPH
TEXT
GRAPH
WIDE
NARROW