Dropping an external payload/test signal, Drop 34 mb/s & ds3, Dropping an external payload/test signal 46 – HP OMNIBER 718 HP 37718A User Manual
Page 56
46
Selecting Test Features
Dropping an External Payload/Test Signal
Dropping an External Payload/Test Signal
Description
You can drop a DSn signal from the received payload or drop 2 Mb/s or
DS1 from the structured DSn signal to external equipment as shown in
the table below. DS3 and 34 Mb/s can only be dropped if SONET is
chosen as the receive interface. 2 Mb/s or DS1 can be dropped from a
structured or non-structured SONET payload and from a structured DSn
signal.
HOW TO:
Drop 34 Mb/s & DS3
1
Connect the 75
Ω
OUT port of the DSn Transmit module to the
external equipment.
2
Set up the receive SONET interface, and choose VT PAYLOAD
,
or
.
If
is chosen, choose the DS3 output level.
RATE
Availability
Option
DS3
SONET
011 Only
34Mb/s
SONET
010 and 011
2Mb/s
DSn & SONET
010 and 011
DS1
DSn & SONET
011 Only
DROP 34 Mb/s
DROP DS3
DROP DS3