Setting receive structured payload/test signal, Setting receive structured payload/test signal 39 – HP OMNIBER 718 HP 37718A User Manual
Page 49
39
Selecting Test Features
Setting Receive Structured Payload/Test Signal
Setting Receive Structured Payload/Test Signal
Description
Structured DSn Payload/Test Signal settings determine the SONET
payload or the DSn test signal to be tested.
TIP:
If you wish to set the HP 37718A transmitter and receiver to the same
Payload settings, choose
.
HOW TO:
1
Choose the required Test Signal rate. If N x 64 kb/s or N x 56 kb/s is
chosen, see "Setting Receive N x 64 kb/s/N x 56 kb/s Structured
Payload/Test Signal " page 42.
2
Choose the Framing pattern of the PAYLOAD.
If TEST SIGNAL 2 Mb/s is chosen,
is added to the
menu. See "Dropping an External Payload/Test Signal " page 46.
If TEST SIGNAL DS1 is chosen,
is added to the menu.
See "Dropping an External Payload/Test Signal " page 46.
3
Choose the test tributary within the structured payload, under 34Mb,
8Mb, 2Mb, 64 kb or DS2, DS1, 56 kb/s.
4
Choose the PATTERN type and PRBS polarity.
OTHER
STORED SETTINGS
COUPLED
DROP 2 Mb/s
DROP DS1