Storing, Logging and Printing

Logging Results

Optional Internal printer fitted into the instrument front cover
(Option 602)

External HP-IB printer (option 601)

External RS-232-C printer (option 601)

External Parallel Port printer (option 601)

Disk Drive

HOW TO:

1

Choose LOGGING [ON] - enables the logging of results and alarms.

2

Choose LOGGING PERIOD - determines how regularly the results
and alarms are logged.
USER PROGRAM provides a choice of 10 minutes to 99 hours.

3

Choose RESULT LOGGED - allows you to log all results to or choose
only those results you require.

4

Choose WHEN - allows you to choose to only log when the error count
for the logging period is greater than 0. If the error count is 0 then the
message NO BIT ERRORS is displayed.

5

Choose CONTENT - allows you a choice of error results to be logged.
Error Results, Analysis or Error and Analysis (ER & ANAL)
and
Period, Cumulative or Period and Cumulative (PER & CUMUL).

6

If LOG ERROR SECONDS [ON] is chosen a timed and dated message
is logged each time an error second occurs (excessive occurrences of
error seconds during the logging period will result in heavy use of