Control and Indicators

Table 1-3

describes how to troubleshoot and solve issues using the Internal Diagnostic Panel

The system event log can be accessed from:

• Instant Toptools
• Toptools
• Navigator CD
• Diagtools

Table 1-3. Using the Internal Diagnostic Panel

LED Name

Error Conditions Corrective Action

Processor

Temperature over
threshold, Internal
CPU Error

1. Check the system event log to view error details. If CPU is over the

temperature threshold, verify that the heat sink and thermal grease
are installed properly--call HP Customer Care. Also check items in
the System Temperature section below.

2. If errors are not resolved, try rebooting the server to resolve the

error.

Memory
DIMM

ECC double and
single bit errors

1. Check the system event log to view error details. If the error is a pre-

dictive failure, you may continue to operate the Server, however, the
DIMM should be replaced as soon as possible to avoid unscheduled
downtime. If the error is a double-bit uncorrectable error, the
DIMM should be replaced immediately.

2. If other errors occur, power down the server, unplug the server from

its power source, re-seat the DIMM, and restart the HP Server
tc4100.

System Fan

Incorrect fan
speed, predictive
fan failure, fan
failure

1. Reseat system fan module.
2. If the error is not resolved, replace the system fans.

System Board System board

voltage level error

Reboot the HP Server tc4100.

Memory
Configuration

Incorrect memory
type

Check that the installed memory is HP PC133 ECC SDRAM memory.
If this is not correct, replace all DIMMs that are not HP PC133 ECC
SDRAM memory.

Processor
Configuration

Incompatible
Stepping

Check the stepping of the processors. Replace any processors that do
not have compatible steppings.

System
Temperature

Temperature over
threshold

Check the following:
• All system fans are operational
• CPU heat sink is installed correctly on processor with thermal

grease--call HP Customer Care.

• Room temperature within supported temperature range. See Chapter

9 for Environmental Requirements.

• All covers, filler panels and air ducts are installed correctly.
• Adequate ventilation
• Check system event log for further details
If none of the above steps resolves the problem, reboot HP Server
tc4100.

Check Event
Log

Many errors

Check the system event log to view error conditions.