Hardware specifications plx8x-eip-61850, Leds – ProSoft Technology PLX81-EIP-61850 User Manual
Page 83

PLX8x-EIP-61850 ♦ Communication Gateway
Reference
Server to
IEC 61850 Client
User Manual
ProSoft Technology, Inc.
Page 83 of 167
July 2, 2015
5.2
Hardware Specifications PLX8x-EIP-61850
Specification
Description
Power Supply
24 VDC nominal
10 to 32 VDC power input allowed
Positive, Negative, GND Terminals
2.5 mm screwdriver blade
Current Load
200 mA maximum @ 24 VDC
150 mA maximum @ 32 VDC
450 mA maximum @ 10 VDC
Operating Temperature 32°F to 140°F (0°C to 60°C)
Storage Temperature
-40°F to 185°F (-40°C to 85°C)
Relative Humidity
5% to 95% RH, with no condensation
Dimensions
Standard: Height x Width x Depth
4.72 inches x 1.90 inches x 4.18 inches
Ethernet Port (E1)
10/100 Base-T half duplex RJ45 Connector
Link and Activity LED indicators
Electrical Isolation 1500 V rms at 50 Hz to 60 Hz for 60 s, applied as
specified in section 5.3.2 of IEC 60950: 1991
Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP]
frames-per-second and less than or equal to 5 minutes duration
LED Indicators
ERR, CFG, FLT, PWR
Shock and Vibration
Shock and Vibration tested to EN 60068 Standard
Shipped with Each Unit One - Ethernet straight-through cable
One - J180 screw terminal plug
One - ProSoft Solutions DVD
One - HRD250 screwdriver
One - 1GB Industrial SD Card
5.3
LEDs
LED
State
Description
Pwr
Off
Power is not connected to the power terminals or source is
insufficient to properly power the gateway (800mA at 24 VDC
minimum required)
Pwr
Green Solid
Power is connected to the power terminals. Verify that the other
LEDs for operational and functional status come on briefly after
power-up (check for burned-out LEDs).
Flt
Off
Normal operation
Flt
Red Solid
A critical error has occurred. Program executable has failed or has
been user-terminated and is no longer running. Press Reset p/b or
cycle power to clear error.
Cfg
Off
Normal operation
Cfg
Amber Solid
The unit is in configuration mode. The configuration file is currently
being downloaded or, after power-up, is being read, the unit is
implementing the configuration values, and initializing the hardware.
This occurs during power cycle, or after pressing the reset button. It
also occurs after a cold/warm boot command is received.
Err
Off
Normal operation
Err
Flashing
An error condition has been detected and is occurring on one of the
application ports. Check configuration and troubleshoot for
communication errors.
Err
Solid Amber
This error flag is cleared at the start of each command attempt